Fencing systems

 I. fencing gates and wickets - a

I. fencing gates and wickets - b

II. fencing segments and posts

 II. fencing segments - filling catolologue

  

Fencing  systems

I. Driveway fence gates and wickets

 q       LIST OF QUESTIONS to let you order properly fencing doors and wicket doors 

  1. Type (sliding: FOR PRIVATE HOUSES, EKO, INDUSTRIAL, DOUBLE-LEAF gate, WICKET - to be determined after having read the contents of the chapter)?

  2. What is the driveway (mounting opening) width in which gate or wicket is to be assembled?

  3. How high is the gate or wicket leaf?

  4. What is the direction of opening the gate or wicket?

  5. What kind of paling do you want?

  6. What kind of corrosion protection do you want?

  7. Do you want a manual or automatic gate (additional transmitters)?

  8. Optional equipment? 

Types of HANDLOPOL AB fencing gates

 WISNIOWSKI company offers:

  • sliding fencing gates: for private houses, Eko, industrial,

  • double leaf fencing gates,

  •  wickets.

Give the type of the gate ordered in the table. 

Determining gate and wicket ordering dimensions

Basic data to be determined while placing an order for sliding gates (see fig. 1- 5):

  • gate driveway width,

  • gate height (in the case of a gate without paling give the height of the construction and additionally the height of planned paling acc. to figure from pages 4J -  5 J).

For private houses sliding gate maximum dimensions are 6000 x 1950 [mm] (driveway width x gate height). Typical dimensions: 3500 x 1450 [mm] (driveway width x gate height).

Its structure is made of steel sections (guiding section is made of half-closed section 80 x 80 [mm]).


Textruta: Fig. 1
Sliding gate - for private houses with AWso 93-02drive unit - above 5000 [mm] of driveway width, right, the premises view.
Textruta: DRIVEWAY WIDTH (INSIDE DIMENSION)*
Textruta: TOTAL GATE LENGTH
Textruta: DISTANCE BETWEEN BOLTS*
Textruta: *) - These dimesions must determined when ordering
Textruta: GATE HEIGHT*

 

 

 

 

 

 


Textruta: Fig. 2 
Sliding gate - for private houses with AWso 2000 drive unit in the post - (standard equipment: signalling lamp, outer antenna) right premises view
Textruta: DRIVEWAY WIDTH (INSIDE DIMENSION)*
Textruta: TOTAL GATE LENGTH
Textruta: DISTANCE BETWEEN BOLTS*
Textruta: *) - These dimesions must determined when ordering
Textruta: GATE HEIGHT*

 

 

 

 

 

 


 

Textruta: GATE HEIGHT*
Textruta: DRIVEWAY WIDTH (INSIDE DIMENSION)*
Textruta: TOTAL GATE LENGTH
Textruta: DISTANCE BETWEEN BOLTS*
Textruta: *) - These dimesions must determined when ordering
Textruta: Fig. 3
Sliding gate - for private houses manually opened, up to 5000 [mm] of driveway width, additionally equipped with the drive unit AWso 93-01, right, premises view

 


 

Eko sliding gate maximum dimensions are 3800 x 1450 [mm] (driveway width x gate height). Typical dimensions: 3500 x 1250 [mm] (driveway width x gate height).

Its structure is made of steel sections (guiding section is made of half-closed section 50 x 55 [mm]).


Textruta: Fig. 4
Sliding gate - for private houses - Eko manually opened, right, premises view
Textruta: DRIVEWAY WIDTH (INSIDE DIMENSION)*
Textruta: TOTAL GATE LENGTH
Textruta: DISTANCE BETWEEN BOLTS*
Textruta: *) - These dimesions must determined when ordering
Textruta: GATE HEIGHT*

 

 

 

 

 

 


Textruta: Fig. 5
Sliding gate - for private houses automatically opened, with the drive unit AWso 2000, in the post, right, premises view
Textruta: DRIVEWAY WIDTH (INSIDE DIMENSION)*
Textruta: TOTAL GATE LENGTH
Textruta: DISTANCE BETWEEN BOLTS*
Textruta: *) - These dimesions must determined when ordering
Textruta: GATE HEIGHT*

 

 

 

 

 

ATTENTION !  Total door length = driveway width + distance between bolts + 400 [mm]

 

 

 

Textruta: DRIVEWAY GATES CONSTRUCTION (right)
Textruta: Pos height
Textruta: gates post Post height = height of planned paling + 10 cm (ordering dimension)
Textruta: Construction height (ordering dimension)
Textruta: 60 ÷ 80 mm
Textruta: Planned paling height 
Textruta: Finished driveway level
Textruta:  Distance between  bolts (anchors) determined when ordering

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

  Textruta: OPENING DIRECTION (PREMISES VIEW)

 

 

 

 

 

 

 

 

 

 

 

 

 

Textruta: DRIVEWAY GATES CONSTRUCTION (left)
Textruta: Distance between bolts (anchors) determined when ordering
Textruta: Finished driveway level
Textruta: Planned paling height
Textruta: 60 ÷ 80 mm
Textruta: gates post Post height = height of planned paling + 10 cm (ordering dimension)
Textruta: Post height
Textruta: Construction height (ordering dimension)

 

 

 

 

 

 

 

 

 

Textruta: OPENING DIRECTION (PREMISES VIEW)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Textruta: SLIDING GATE  (left) - mounting instructions dimensions are given in [mm]
Textruta: Mounting reserve ok. 700
Textruta: 300 ÷ 500
Textruta: Control wires for photocell YLY 2x0,5
Textruta: Line of fence system
Textruta: PREMISES
Textruta: YLY 2x0,5 control with button
Textruta: Mounting reserve about 1000(2)
Textruta: M 16 or M 20(in dependence on the gate size)
Textruta: Finished 
driveway level
Textruta: 1) PREMISES VIEW
Textruta: 2) TOP VIEW
Textruta: B – prepared for AWso 93-01 drive unit
Textruta: Foundation
Textruta: Place of supply, control wires  insert, and for photocells mounting reserve 1000(2)
Textruta: 120
Textruta: 90
Textruta: 140
Textruta: 60
Textruta: 250
Textruta: 140
Textruta: Distance between foundation bolts (anchors) determined when ordering
Textruta: 140
Textruta: B
Textruta: Foundation for left sliding gate
Textruta: Foundation bolt
Textruta: (1)  Supply wires with the distance from the supply source  £ 30 [m] YLY 2x1,5, and with the bigger distance YLY 2x2,5
(2)  For automatic gates mounting reserve 1000, for manual gates with the drive unit AW to be assembled later  on mounting reserve is 2000
 ATTENTION !   Do not change intersections of supply wires and control wires it world cause mounting difficulties.
Textruta: 1200 - 1400
Textruta: 120
Textruta: 140
Textruta: 120
Textruta: 60
Textruta: 20
Textruta: B - for automatic gate
Textruta: Foundation bolt
Textruta: Foundation bolt
Textruta: Foundation
Textruta: 80
Textruta: A
Textruta: A
Textruta: Fence post
Textruta: YLY 2x1,5(1)
Textruta: Line of gate track
Textruta: Radiation barrier (optional equipment)
Textruta: Finished driveway level
Textruta: YLY 4x0,5 photocells
Textruta: Driveway width
Textruta: Fence post
Textruta: Fence post

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Textruta: SLIDING GATE  (right) - mounting instructions dimensions are given in [mm]

Textruta: Fence post
Textruta: Fence post
Textruta: Driveway width
Textruta: Control wires for photocell YLY 2x0,5
Textruta: Line of fence system
Textruta: YLY 2x1,5(1)
Textruta: YLY 2x0,5 control with button
Textruta: Mounting reserve about 1000(2)
Textruta: 250
Textruta: 140
Textruta: Distance between foundation bolts (anchors) determined when ordering
Textruta: 140
Textruta: B
Textruta: Foundation for right sliding gate
Textruta: Foundation bolt
Textruta: 1) PREMISES VIEW
Textruta: A
Textruta: 80
Textruta: Foundation
Textruta: Foundation bolt
Textruta: Foundation
Textruta: Foundation bolt
Textruta: Place of supply, control wires insert, and for photocells mounting reserve 1000(2)
Textruta: B - for automatic gate
Textruta: 120
Textruta: 90
Textruta: 20
Textruta: 140
Textruta: 120
Textruta: 60
Textruta: 60
Textruta: 140
Textruta: 2) TOP VIEW
Textruta: B – prepared for AWso 93-01 drive unit
Textruta: Finished 
driveway level
Textruta: M 16 or M 20(in dependence on the gate size)
Textruta: (1)  Supply wires with the distance from the supply source  £ 30 [m] YLY 2x1,5, and with the bigger distance YLY 2x2,5
(2)  For automatic gates mounting reserve 1000, for manual gates with the drive unit AW to be assembled later  on mounting reserve is 2000
 ATTENTION !   Do not change intersections of supply wires and control wires it world cause mounting difficulties.
Textruta: 1200 - 1400
Textruta: 120
Textruta: A
Textruta: Fence post
Textruta: Line of gate track
Textruta: PREMISES
Textruta: YLY 4x0,5 photocells
Textruta: Radiation barrier (optional equipment)
Textruta: Finished driveway level
Textruta: 300 ÷ 500
Textruta: Mounting reserve
ok. 700

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Textruta: Mounting reserve ca 700

 


 

 

 Textruta: Foundation thickenedconcrete B20

Textruta: SLIDING INDUSTRIAL GATE (left) - mounting instructions dimensions are given in [mm]
Textruta: min. 1000 but below the freeze zone acc. to PN-81/B-03020

Textruta: 400
Textruta: 146
Textruta: Driveway width
Textruta: Control wires for photocell YLY 2x0,5 in steel or PCV pipe
Textruta: YLY 3x1,5 power supply
Textruta: 230
Textruta: Mountig reserve 1000
Textruta: Foundation bolts (anchor) of reinforced concrete bar 25-18G2 PN-82/H-95215 lenght 500
Textruta: 500
Textruta: A
Textruta: 165 ± 2
Textruta: Place of wires inserting
Textruta:  75
Textruta: 130
Textruta: YLY 2x0,5 control with button
Textruta: Detail A
Textruta: Detail B
Textruta: M16
Textruta:     80
Textruta:  350
Textruta: NOTICES:   -  Ends of anchors shall be placed on the same level   -  Keep COAXIALITY when placing the concrete of bolts -  Keep plumb line when mounting bolts   -  Do not change intersections of supply wires and control wires it world cause mounting difficulties.
Textruta: 130
Textruta:  60
Textruta:   80
Textruta: M20
Textruta: Detail C
Textruta:  60
Textruta: C
Textruta: 175
Textruta: Foundation bolt (anchor)
Textruta: 350
Textruta: 80
Textruta: min. 1000
but below the freeze zone
acc. to PN-81/B-03020
Textruta: Foundation thickened concrete B20
Textruta: 1990
Textruta: 2880
Textruta: 230
Textruta: Mountig reserve 1000
Textruta: Foundation bolts (anchor) of reinforced concrete bar 25-18G2 PN-82/H-95215 lenght 500
Textruta: Radiation barrier
Textruta: Finished diveway level
Textruta: YLY 4x0,5 (photocells)
Textruta: min. 500
Textruta: B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Textruta: min. 1000 but below the freeze zone acc. to PN-81/B-03020

 

  

Textruta: Foundation bolt s(anchor) of reinforced concrete bar 25-18G2 PN-82/H-95215 lenght 500
Textruta: min. 1000 but below the freeze zone acc. to PN-81/B-03020

 

 

 

 


 

Textruta: SLIDING INDUSTRIAL GATE (left) - mounting instructions dimensions are given in [mm]
Textruta: min. 1000 but below the freeze zone acc. to PN-81/B-03020
Textruta: B
Textruta: min. 500
Textruta:  350
Textruta: Driveway width
Textruta: Control wires for photocell YLY 2x0,5 in steel or PCV pipe
Textruta: YLY 3x1,5 power supply
Textruta: Detail A
Textruta: M20
Textruta:   80
Textruta: 230
Textruta: 1990
Textruta: 2880
Textruta: Foundation thickenedconcrete B20
Textruta: Foundation bolt (anchor)
Textruta: 175
Textruta: 130
Textruta:  75
Textruta: Detail C
Textruta:      80
Textruta: 165 ± 2
Textruta: 350
Textruta: 500
Textruta:  60
Textruta: C
Textruta: Place o wirs inserting 
Textruta: A
Textruta: Mountig reserve 1000
Textruta: 230
Textruta:     80
Textruta: M16
Textruta: Detail B
Textruta: YLY 2x0,5 control with button
Textruta: Mountig reserve 1000
Textruta: Foundation bolts (anchor) of reinforced concrete bar 25-18G2 PN-82/H-95215
lenght 500
Textruta: Radiation barrier
Textruta: Finished driveway level
Textruta: YLY 4x0,5 (photocells)
Textruta: 130
Textruta:  60
Textruta: 146
Textruta: 400
Textruta: Foundation
thickened
concrete B20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Textruta: Foundation thickenedconcrete B20

Textruta: Foundation thickenedconcrete B20

  

 

Fencing systems

 I. fencing gates and wickets - a

I. fencing gates and wickets - b

II. fencing segments and posts

 II. fencing segments - filling catolologue

 Colours according to RAL palette

 

GARAGE DOORS ENGLISH

Overhead doors

Double leaf doors

Steel doors

Suspended sliding

EuroPro sektional

BR-77s roller

BR-77s-bs rooler

BR-77w roller

INDUSRTIAL DOORS

BR-100 roller ALU

MakroPro sektional

MakroPro ALU

FENCING SYSTEMS

Driveway fence gatees and wickets A

Driveway fence gatees and wickets B

Fencing segments and posts

Fencing segments - filling

NEWS - fencing segments filling  and posts

ROLLER BLINDS

RAL colours map

ALUMINIUM JOINERY

PRICE LIST - garage doors - pdf

FEEDBACK


INDEX

Home Page HANDLOPOL

LEVERANSVILLKOR

ÅF -ansökan

e-mail

Contens English

Contact Information

 HANDLOPOL SVENSKA AB

Telephone
+46 (0) 31 336 35 53
+46 (0) 708 10 11 91
FAX
+46 (0) 31 336 35 01
Postal adress
HANDLOPOL AB
Gamla kronv. 10
S-433 33 Partille (Göteborg)
SWEDEN
e- mail:  info@handlopol.se

General Information: Handlopol AB

http://www.handlopol.se/garageportar


© 1991-2004. Dessa sidor tillhör Handlopol Svenska AB.
Eftertryck/kopiering medges om tillstånd inhämtats hos
Handlopol Svenska AB och vid publicering skall källan tydligt anges.

Skicka e-post till   info@handlopol.se med frågor eller kommentarer om den här webbplatsen.
Copyright © 1991 HANDLOPOL SVENSKA AB
Senast ändrad:
 11 september 2004