Fencing systems
I. Driveway fence gates and wickets

Industrial
sliding door maximum dimensions are 9000 x 2200 [mm] (driveway width x gate
height). Its structure is made of steel sections and paling is welded into
the structure.
   ![Textruta: TOTAL GATES LENGTH = DRIVEWAY WIDHT + 3000 [mm]](fencing__systems_b-filer/image010.gif)
Basic
data to be determined while placing an order for
double-leaf
gates and wickets:
mounting opening clearance,
gate (wicket) height.
Double-leaf
gate maximum dimensions are 6000 x 1950 [mm] (driveway widht x door height).
Its structure is made of steel sections as in sliding doors.

    
 


   
ATTENTION !
inside width = opening width about 110 [mm].
Maximum dimensions of the wicket gate 1350x1950 [mm] ( opening width x
wicket height)
Give gate dimensions in [mm] in the table.
Opening direction, distance between bolts (anchors)
Sliding doors may be opened onto right or left side.
ATTENTION !
Opening direction must be always determined taking into account premises
view.
Mounting distance between bolts in a property sliding door is shown in Fig.
9.



![Textruta: distance between bolts [mm] (assembly anchors), M16 - for driveway width of up to 5000 [mm], M20 - for driveway width of more than 5000 [mm]](fencing__systems_b-filer/image031.gif)
.
9.
Assembling
distance between bolts in an
Eko
door is shown in Fig. 10.


  ![Textruta: Distance between bolts [mm] (assembling anchors M16)](fencing__systems_b-filer/image037.gif)
ATTENTION
!
In
industrial
doors assembling distance between bolts is constant and does not change with
the driveway width. Every time with a set of bolts you get their placing
diagram.
In
double-leaf
gates their opening direction has to be given: towards premises inside or
towards its outside.
(ATTENTION
!
opening fencing doors towards premises outside does not comply with the
building regulations in force).
If not given otherwise, a double-leaf gate or a wicket opened towards
premises inside will be made with traditional hinges, while a door opened to
the street will be made with hinges in the door axle, see Fig. 11. At the
client's request any gate may be made with hinges in the axle, but it must
be clearly stated in notes on the order form.
       
For
wicket,
opening direction is to be determined from the following figures. Types of
hinges are the same as for double-leaf gates. Unless stated otherwise, a
wicket opened towards property inside will be made with traditional hinges,
while
a wicket opened towards the premises outside will be made with hinges in the
wicket axle.
 Standard
wicket equipment is a lock with a handle. It is available to have a wicket
made with an electromagnetic lock (write
yes
in the column
"control”).
             
For any fencing gate pay particular attention to:
-
correct execution of base of foundation
ABSOLUTELY BELOW THE ZONE OF FROST PENETRATION
settled for a given region
(according to the Standard PN-81/B-03020),
-
assembling anchor plumbing and coaxial position,
-
placing supply and control cables according to the diagram.
This concerns also a base of foundation for a grab.
Give gate or wicket opening direction and distance between bolts in the
table.
Types of paling are shown in table "Types of segments, gates, wickets
paling" in part devoted to fence segments on page 4K - 8 K.
ATTENTION
!
Any gate or wicket (apart from Eko gate) may be made as the structure itself
prepared for the client to be filled individually in their own capacity. In
gates without paling, paling elements may be fixed only by screwing to the
gate leaf (elements must not be welded).
Maximum paling weight that may be applied by the client to the fencing gate
structures: sliding gates (apart from EKO and industrial gates), doble-leaf
gates and wicket - 20 kg per each running metre of the driveway width.
For industrial fencing gates the weight of paling may be maximum - 22 kg per
each runnig metre of the driveway width.
End of paling is ( if not given otherwise):
·
In closed sections covers,
 
   


Gate paling may be a continuation of the existing fencing in the form of
straight, concave or convex wave. Unless stated otherwise, we assume that
the wave starts and finishes in the driveway width.
Is such a case it is indispensable to give:
Following are the examples of drawings - doors with waves.
Examples of gates with waved paling of are shown on fig. 14 p. 14J
.
ATTENTION
! According to the Decree of Minister of Economy and Building dated on 12
December 1994 in range of technical conditions that building and their
placing should comply with (Part 9 paragraph 43.I) placing on the height
lower than 1800 [mm] barbed wire, smashed glass and other sharply ended
objects is prohibited. In connection with this statement we do inform that
gates, wickets and segments with height below 1800 mm wit filling sharply
ended are destined to be built in fence systems which total height (after
gate mounting, segment, wicket) cannot be lower than
1800 [mm].
On the order form You should indicate the kind of gate, wicket and segment
paling (catalogue number) complying with table on the page 4K -
8 K.

            
Give
the kind of the paling in table.
Corrosion protection, powder coating
Standard corrosion protection (apart from industrial door) is hot
galvanising
(gates with drivewey width above 5500 [mm] are joined after galvanising).
Another corrosion protection may be phosphatising or primer coating.
A
decorative coat is powder coating in colours from the RAL palette or, on
client's special order, surface treatment
with spray painting. Standard colors (every in matt or flat version) RAL
9016, 9005, 8019, 8017, 8014, 8011, 7042, 6029, 5002, 3005, 3000 and also in
structure matt version: RAL 9016, 9005 i 8014.
ATTENTION !
Only gates with the driveway width up to 5000 [mm] may be coated with powder
paint.
(Max. 6900x2400x600)
Give the information about surface protection different from hot galvanising
in the notes as well as the information about surface painting.
Industrial
gates as a standard are phosphatised and primer coated. It is available to
paint them on surface using spraying in any colour of the RAL palette,
double coat with acrylic paints or galvanised, it may, however, to prolong
the time of the gate execution and requires each time to be agreed upon with
the company.
In the table write the type of corrosion protection chosen from possible
ones. If you choose powder coating, give the number of colour from the RAL
palette.
Sliding gates Eko are offered in automatic or manual version. When You
write YES in the column "drive unit" on the order form, You order
automatically opened gate with a drive unit AWso 2000 in the post (
equipment: toothed bar of PCV and two double channel transmitters) Eko
gates in automatic version can be equipped optionally with outer drive unit
3900 mm, remote control with two transmitters, conductory switch.
Sliding gates are offered in automatical or manual version. When You write
Yes in the column "drive unit" on the order form. You order automatic gate
with a drive unit AWso 2000 in the post (equipment: toothed bar of PCV,
signaling lamp, outer antenna and two double channel transmitters) gates up
to 5000 mm of driveway width or gate with outer drive unit AWso 93-02
(equipment: metal toothed bar, two double channel transmitters) - gates
above 5000 mm of driveway width.
For manual sliding gate it is possible to assemble outer drive unit AWso
93-01 or AWso 93-02 (description of the equipment is given above).
ATTENTION !
After prior agreement with the producer, automatic gates above 5000 [mm] of
driveway width and height up to 1650 mm may be equipped with a drive unit
AWso 93-012.
Industrial sliding gates are offered in automatic or manual version. Table
given below presents the offer of drive units for industrial gates.
|
Type of drive unit |
Use |
Equipment |
|
NIOTA |
for gates with driveway width up to 7500 [mm] |
|
|
ONDA 2000 |
for gates with driveway width from 7500 [mm] up to 8500 [mm] |
|
MEC |
for gates with driveway width from 8500 up to 9000 [mm] |
Give the information about the drive unit in the table
"drive unit".
As a standard in automatic gates, in consideration of operation safety, an
overload switch is used.
Optional equipment are photocells. If You wish to buy optional equipment
give the information in the notes.
Double leaf gates are executed as manual gates but on client's request may
be equipped with drive units:
|
PLUTO - for gates with max. leaf width 3000 [mm], in set: remote
control with two transmitters, photocells, outer antenna, conductory
switch. |
|
WINGO 1 - for gates with max leaf width 1800 [mm], in set: remote
control with one transmitter. |
Give the type of the drive unit in table.
You can buy additional transmitters. You should than give the proper
quantity of transmitters.
Fencing
systems
II. fencing segments and posts
II.
fencing segments - filling catolologue
I. fencing gates and wicktes - a
Colours
according to RAL palette
|